{"id":787,"date":"2021-01-10T13:29:38","date_gmt":"2021-01-10T13:29:38","guid":{"rendered":"https:\/\/wiki.graven-ict.nl\/wordpress\/?p=787"},"modified":"2021-01-10T13:36:01","modified_gmt":"2021-01-10T13:36:01","slug":"hddtemp-kent-mijn-hd-ssd-niet","status":"publish","type":"post","link":"https:\/\/wiki.graven-ict.nl\/wordpress\/hddtemp-kent-mijn-hd-ssd-niet\/","title":{"rendered":"HDDtemp kent mijn hd\/ssd niet."},"content":{"rendered":"\n<p>Recent een nieuwe computer gekocht (intel nuc) met 2 SSD&#8217;s. Bij beide ssd&#8217;s worden de temperatuur niet gerapporteerd door hddtemp, hddtemp geeft aan dat hij de disk niet herkent met de volgende melding.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>$ sudo hddtemp \/dev\/sda\nWARNING: Drive \/dev\/sda doesn't seem to have a temperature sensor.\nWARNING: This doesn't mean it hasn't got one.\nWARNING: If you are sure it has one, please contact me (hddtemp@guzu.net).\nWARNING: See --help, --debug and --drivebase options.\n\/dev\/sda: Samsung SSD 860 EVO 250G B              :  no sensor<\/code><\/pre>\n\n\n\n<p>we kunnen als de disk wel een temperatuur sensor heeft deze handmatig in de hddtemp.db plaatsen. hier hebben <em><strong>smartctl<\/strong><\/em> voor nodig als deze niet op het systeem aanwezig is is die te vinden in het package <em><strong>smartmontools<\/strong><\/em> die kan je met favorieten package (<em>apt \/ yum enz.<\/em>) manager installeren. Controleer met smartctl of er een temperatuur output aanwezig is.<\/p><div id=\"grave-2648542395\" class=\"grave-content grave-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-1970734611769428\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:inline-block;width:728px;height:90px;\" \ndata-ad-client=\"ca-pub-1970734611769428\" \ndata-ad-slot=\"1820224830\"><\/ins> \n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<pre class=\"wp-block-code\"><code>$ sudo smartctl -a \/dev\/sda\nsmartctl 7.1 2019-12-30 r5022 &#91;x86_64-linux-5.4.0-59-generic] (local build)\nCopyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org\n\n=== START OF INFORMATION SECTION ===\nModel Family:     Samsung based SSDs\nDevice Model:     Samsung SSD 860 EVO 250GB\nSerial Number:    S3YJNJ0N600090L\nLU WWN Device Id: 5 002538 e30651dfa\nFirmware Version: RVT04B6Q\nUser Capacity:    250,059,350,016 bytes &#91;250 GB]\nSector Size:      512 bytes logical\/physical\nRotation Rate:    Solid State Device\nForm Factor:      2.5 inches\nDevice is:        In smartctl database &#91;for details use: -P show]\nATA Version is:   ACS-4 T13\/BSR INCITS 529 revision 5\nSATA Version is:  SATA 3.2, 6.0 Gb\/s (current: 6.0 Gb\/s)\nLocal Time is:    Sun Jan 10 12:36:19 2021 UTC\nSMART support is: Available - device has SMART capability.\nSMART support is: Enabled\n\n=== START OF READ SMART DATA SECTION ===\nSMART overall-health self-assessment test result: PASSED\n\nGeneral SMART Values:\nOffline data collection status:  (0x00)\tOffline data collection activity\n\t\t\t\t\twas never started.\n\t\t\t\t\tAuto Offline Data Collection: Disabled.\nSelf-test execution status:      (   0)\tThe previous self-test routine completed\n\t\t\t\t\twithout error or no self-test has ever \n\t\t\t\t\tbeen run.\nTotal time to complete Offline \ndata collection: \t\t(    0) seconds.\nOffline data collection\ncapabilities: \t\t\t (0x53) SMART execute Offline immediate.\n\t\t\t\t\tAuto Offline data collection on\/off support.\n\t\t\t\t\tSuspend Offline collection upon new\n\t\t\t\t\tcommand.\n\t\t\t\t\tNo Offline surface scan supported.\n\t\t\t\t\tSelf-test supported.\n\t\t\t\t\tNo Conveyance Self-test supported.\n\t\t\t\t\tSelective Self-test supported.\nSMART capabilities:            (0x0003)\tSaves SMART data before entering\n\t\t\t\t\tpower-saving mode.\n\t\t\t\t\tSupports SMART auto save timer.\nError logging capability:        (0x01)\tError logging supported.\n\t\t\t\t\tGeneral Purpose Logging supported.\nShort self-test routine \nrecommended polling time: \t (   2) minutes.\nExtended self-test routine\nrecommended polling time: \t (  85) minutes.\nSCT capabilities: \t       (0x003d)\tSCT Status supported.\n\t\t\t\t\tSCT Error Recovery Control supported.\n\t\t\t\t\tSCT Feature Control supported.\n\t\t\t\t\tSCT Data Table supported.\n\nSMART Attributes Data Structure revision number: 1\nVendor Specific SMART Attributes with Thresholds:\nID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE\n  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       -       0\n  9 Power_On_Hours          0x0032   099   099   000    Old_age   Always       -       464\n 12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       -       42\n177 Wear_Leveling_Count     0x0013   099   099   000    Pre-fail  Always       -       1\n179 Used_Rsvd_Blk_Cnt_Tot   0x0013   100   100   010    Pre-fail  Always       -       0\n181 Program_Fail_Cnt_Total  0x0032   100   100   010    Old_age   Always       -       0\n182 Erase_Fail_Count_Total  0x0032   100   100   010    Old_age   Always       -       0\n183 Runtime_Bad_Block       0x0013   100   100   010    Pre-fail  Always       -       0\n187 Uncorrectable_Error_Cnt 0x0032   100   100   000    Old_age   Always       -       0\n190 Airflow_Temperature_Cel 0x0032   068   050   000    Old_age   Always       -       32\n195 ECC_Error_Rate          0x001a   200   200   000    Old_age   Always       -       0\n199 CRC_Error_Count         0x003e   100   100   000    Old_age   Always       -       0\n235 POR_Recovery_Count      0x0012   099   099   000    Old_age   Always       -       39\n241 Total_LBAs_Written      0x0032   099   099   000    Old_age   Always       -       428370514\n\nSMART Error Log Version: 1\nNo Errors Logged\n\nSMART Self-test log structure revision number 1\nNo self-tests have been logged.  &#91;To run self-tests, use: smartctl -t]\n\nSMART Selective self-test log data structure revision number 1\n SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS\n    1        0        0  Not_testing\n    2        0        0  Not_testing\n    3        0        0  Not_testing\n    4        0        0  Not_testing\n    5        0        0  Not_testing\nSelective self-test flags (0x0):\n  After scanning selected spans, do NOT read-scan remainder of disk.\nIf Selective self-test is pending on power-up, resume after 0 minute delay.<\/code><\/pre>\n\n\n\n<p style=\"text-align: left;\">in de bovenstaande output lijkt de temperatuur te staan op id 190, dit id hebben we nodig om de hddtemp.db bij te werken. wat moeten we nog meer hebben. De modelname van de drive waarmee de drive herkent kan worden in dit geval vind je die terug in de hddtemp output zelfs maar ook in de output van smartctl, welke eenheid de temp aangeeft, in dit geval C(elcius) en is er nog plek voor een omschrijving. <br><em>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Samsung SSD 860 EVO 250G&#8221;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 190&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; C&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &#8220;Samsung SSD 860 EVO 250G&#8221;<br><br><\/em>boven staande regel voegen je dus toe aan de hddtemp.db in mijn geval staat deze in \/etc\/ dit kan bij jouw dus een andere plek zijn. na het toevoegen geeft hddtemp netjes de temp aan.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>$ sudo hddtemp  \/dev\/sda\n\/dev\/sda: Samsung SSD 860 EVO 250G B              : 33\u00b0C\nedwin@andromeda:\/etc\/netplan$ \n<\/code><\/pre>\n","protected":false},"excerpt":{"rendered":"<p>Recent een nieuwe computer gekocht (intel nuc) met 2 SSD&#8217;s. Bij beide ssd&#8217;s worden de temperatuur niet gerapporteerd door hddtemp, hddtemp geeft aan dat hij de disk niet herkent met de volgende melding. we kunnen als de disk wel een temperatuur sensor heeft deze handmatig in de hddtemp.db plaatsen. hier hebben smartctl voor nodig als ..<\/p>\n<div class=\"clear-fix\"><\/div>\n<p><a href=\"https:\/\/wiki.graven-ict.nl\/wordpress\/hddtemp-kent-mijn-hd-ssd-niet\/\" title=\"Meer lezen...\">Lees meer<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[4,1],"tags":[79,75,78,77,76],"class_list":["post-787","post","type-post","status-publish","format-standard","hentry","category-algemeen","category-uncategorized","tag-harddisk","tag-hddtemp","tag-sda","tag-ssd","tag-temperatuur"],"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/wiki.graven-ict.nl\/wordpress\/wp-json\/wp\/v2\/posts\/787","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wiki.graven-ict.nl\/wordpress\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wiki.graven-ict.nl\/wordpress\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wiki.graven-ict.nl\/wordpress\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/wiki.graven-ict.nl\/wordpress\/wp-json\/wp\/v2\/comments?post=787"}],"version-history":[{"count":4,"href":"https:\/\/wiki.graven-ict.nl\/wordpress\/wp-json\/wp\/v2\/posts\/787\/revisions"}],"predecessor-version":[{"id":792,"href":"https:\/\/wiki.graven-ict.nl\/wordpress\/wp-json\/wp\/v2\/posts\/787\/revisions\/792"}],"wp:attachment":[{"href":"https:\/\/wiki.graven-ict.nl\/wordpress\/wp-json\/wp\/v2\/media?parent=787"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wiki.graven-ict.nl\/wordpress\/wp-json\/wp\/v2\/categories?post=787"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wiki.graven-ict.nl\/wordpress\/wp-json\/wp\/v2\/tags?post=787"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}